Signs that Your Computer is Poorly Organized. If your computer is a mess, you’re probably already aware of it. But just in case you’re not, here are some tell. Smart Copies are created in the same way as Junctions, select a folder, click the Action button, choose Pick Link Source from the action menu. I recently purchased a new Yoga 2 Pro with a gorgeous 3200 x 1800 display. My main purposes for this device was to do some heavy lifting on the the road with. This plugin for Adobe Lightroom adds many new location-based features to Lightroom, and enhances or replaces some features Lightroom already has, including: This. Adobe Flash Builder 4.6 or later makes it easy for you to build mobile apps for a variety of devices using the same workflow you use to build web or desktop. Auto. CAD Electrical Tutorials Webinars Tips and Tricks. HOME REFERENCES TIPS/TRICKS LINKS CONTACTWelcome to Electrical Computer- Aided Design Consulting Headquarters Doug Mc. Alexander, Inc. Auto. CAD Electrical Training and Implementation Support. Certified Autodesk Auto. CAD Electrical Expert Elite. Tips and Tricks Pre- paid phone/e- mail/video support is available. Develop the basic border drawing for your company. Create a project called Border. Don't worry about putting any drawings in it. Inside the Border Template folder create a new text file named Border. Note: Auto. CAD. If neither is found in the project folder it will search the User folder for default. This WDL file controls the language of the prompts you get when you right click a project name in the Project Manager and select Descriptions to enter the project line label data. The default is LINE1, LINE2, etc. The syntax for this file is as follows. LINE1=your prompt here (i. Project Description: )LINE2=your next prompt here (i. Drawing No.: )LINE3=your next prompt here (i. Revision Level: ). Click the Project menu tab and select Title Block Setup. This method automatically creates a mapping attribute named WD. Click the drop- down arrows next to each Project Line Label prompt and assign select the attribute you want the data delivered to during the Title Block Update operation. Click on Drawing Values button at lower right. Save the border drawing as something like D. Hint: The easiest way to find the template folder is to temporarily change the Save. As Type setting to . Click Insert from the pull- down menu, select Block, and browse to the Template folder. Click the Drawing Properties icon from the Schematic menu tab. Click Create/Edit Wire Type from the Edit Wire menu. Note: Don't forget to assign a layer color and line type. Hint: You cannot assign a color or line type until you click in another cell after typing in the wire type information. Insert some wires and components to create a sample circuit, so you can adjust color and line type assignments. The color is usually green or blue. Type LTSCALE at the command line and press the Enter key on your keyboard to adjust the line type scale until your dashed line types appear as fine or coarse as you desire. Enter your desired default text height and press enter. Finally, click File> Save. As and set the Save. As type to . dwt for template. This allows you to edit legacy Auto. CAD drawings and mechanical drawings with the same software that you use to create electrical control system wiring diagrams. I was resistant to the Ribbon menu at first but, as an instructor, I quickly realized its benefits for new users. From the Conversion Tools menu tab click the Change/Convert Wire Type button and convert the lines that represent wires into wire type layers you defined in your Auto. CAD Electrical drawing template. If your old drawing contained ladders, use the Convert Ladders utility to convert the plain text line reference numbers (a. Use the Block Replacement utility to swap symbol blocks from the old drawing for those recognized by Auto. CAD Electrical. Hint: The Project option can be used if you have already created every drawing you need and you have already copied with a base point the non- ACE compliant drawing data into each of the new drawings. You can alternatively swap one block at a time using the Convert to Schematic Component tool, which is also located on the Conversion Tools menu tab. Use the Convert Text to Wire number tool to convert any existing text- based wire numbers to smart wire numbers. There is a Stretch Wire utility included on the Conversion Tools menu tab, in case some of the intelligent replacement symbol blocks are smaller than the originals and thus the wires did not completely attach to their respective wire connection attributes. After all, on a large scale project, these might each be created by different designers. This can be accomplished within the Project Manager of Auto. CAD. Right click the schematic only project and select Add Drawings. Document Number, Job Number, Drawn By, Checked By, Date, Revision, etc.). Execute a separate Title Block Update for each . See the screen shot below: If you work with sub- projects on a regular basis, you may be interested in a utility we sell, called Super Project Manager. This is due to network traffic/latency. CR, LT, SS, PB, etc.). When you click Lookup you will see that the top left box under Catalog is blank. You can uncheck if you wish not to copy the project specific support files. See example below. The POSITION attributes hold the text value that you can assign to the various positions of a selector switch. NO, 2 for NC, or 3 for Form- C), followed by a comma followed by the first contact terminal or pin assignment (i. A1. X), followed by the second contact terminal or pin assignment (i. A1. Y), followed by a a semicolon as a delimiter to start the next group. The WDBLKNAM field in the catalog database is used by the Symbol Name Filtering function. HCR1 and VCR1). I am now ready to insert the N. O. For example, NOAUX; 2,NCAUX will get one NO aux contact and 2 NC aux contacts. First, insert the wires that will be summed into one line. TSE) to insert the terminal strip. BOM) as a separate device. Until Autodesk enhances the Terminal Strip Editor and the Terminal Properties database to accomodate this need, what I do is edit the terminal properties to redefine the block as a 3- level block, internally- jumpered, allowing one wire per connection, as shown below. I would envision the terminal properties and the TSE interface could be enhanced such that we could define the number of wires per connection for each connection, left and right, and thus the interface would gray out the areas where no wire could be connected. Starting with version 2. Auto. CAD. Take for example a 1. TB3 terminal board for A- B Flex I/O modules. This part may appear as a multiple catalog item under several . This is because Auto. CAD. But with a Tallied Purchase List Format you prefer a simple sum total tally of all parts, according to item number. In fact you only want to see each Item number listed once on the BOM. But then your 1. 79. IR8 might be item number 7. Multiple Catalog list would be item number 7. TB3 is listed as a Multiple Catalog part under the 1. IR8 as well as under the 1. IB1. 6. I have had this scenario with fuses and fuse holders, control relays and their bases and clips, and with such parts as the 1. TB3 Flex I/O terminal board. These will not provide the report format you seek. Insert a Generic Marker from the Panel Layout> Insert Footprint> Manual menu. You will see the MFG and CAT attributes that you assign, but no geometry. Hint: You can manually type in the tag of the master part this item goes with if you want it to be a . I place the Generic Marker above or below by Flex I/O footprint. The footprint looks like a Flex I/O module plugged into a 1. TB3 terminal board. So the master part number is assigned to the footprint. I then insert a Generic Marker above or below the Flex I/O footprint and assign MFG as AB and CAT as 1. TB3. I manually type in the Tag assignment of the master that this 1. TB3 is associated with. The quantity should be 1. Be sure to assign an Item Number. I will insert a Generic Marker next to each of the Flex I/O footprints. Each will have a different Tag assignment but will carry the same MFG, CAT, and ITEM assignment. This will result in one sum total listing for all 1. TB3 boards, regardless of the master part they are associated to. In the image below you see a Generic Marker located directly above the Flex I/O module. This method is . You think of your panel footprints in pieces. For example, the 1. TB3 is installed in the panel and the 1. IB1. 6 is then plugged into it. In the case of a control relay, you install the relay base, then the relay, and finally the clips. So with this method I actually create multiple footprints, each with a complete set of Panel Footprint Attributes. So in the case of the Flex I/O and its terminal board I split the Flex I/O footprint into two separate blocks, one to represent the 1. TB3 terminal board and the other to represent the module. I use a common base point for each footprint block so I can overlay them accurately. I usually insert the base device using the Browse feature on the Panel Layout> Insert Footprint menu. I list the Flex I/O module in the footprint lookup database so it is inserted using the Insert Footprint from Schematic List function on the Panel Layout toolbar. In other words, the actual part number that is common to both the schematic and the panel layout is the 1. IB1. 6 so this is the one I enter into the Footprint Lookup database. But the terminal board will only appear in the panel layout, so it gets inserted as a separate footprint using the Browse button. You can insert the terminal boards before inserting the modules (if you know how many you need), or you can insert the terminal board after you have inserted the module footprints. Below is an example using method 2 to insert the three parts that make up a control relay, each with its own set of attributes, so each can be assigned a separate item number. See screen images below. Another approach to sub- assembly parts is the Multiple Catalog method. HFU1) followed by two . HFU2, adapting to virtually any wire spacing. Electrical then automatically joins the three separate fuse symbols together with a dashed link line to give the appearance of a 3- pole fuse. In the Footprint Database, I have the class create an entry for the fuse part number that calls up this single pole footprint. HCB1) and two . HCB2, adapting to virtually any wire spacing. Electrical then automatically joins the three separate symbols together with a dashed link line to give the appearance of a 3- pole device. You can use the wd. It then searches the active library for the same symbol name as the parent symbol, but with a . Pole Circuit Breaker). In the case of a laptop that you travel with, you can rename the Ae. Configuration Manager 2. R2 Client Installation. Configuration Manager 2. R2 Client Installation In this post we will discuss about the Configuration Manager 2. R2 Client Installation methods, we will also configure the network access account that is a must before you perform Configuration Manager 2. R2 Client Installation. Configuration Manager 2. R2 Client Installation can be done in various ways, before you can use Configuration Manager to manage a system, you must discover the system and install the client. In my previous posts we have seen how to configure Configuration Manager 2. R2 Boundaries and Discoveries, so once the systems are discovered you can proceed with Configuration Manager 2. R2 Client Installation. At any point of time you can jump to configuration manager 2. R2 step by step guide for my previous posts. Configuration Manager 2. R2 Client Installation. Lets look at the methods available for Configuration Manager 2. R2 Client Installation, we will be deploying the clients using client push installation in this post. Client Push Installation – Client Push Installation happens when an the SCCM server makes a network connection to the client (a machine where configuration manager client is to be installed) and then begins the client installation process. For this the system must be discovered and the administrator should have configured the firewall exceptions. This method requires the administrator to start the client push installation on selected computers. Automatic Sitewide Client Push Installation – In Automatic sitewide Client Push Installation method you can configure client push installation for a site, and client installation will automatically run on the computers that are discovered within the site’s configured boundaries when those boundaries are configured as a boundary group. Software update point installation – This method installs the client by using the Configuration Manager software updates feature. No prior discovery of system is required in this method. Manual Installation – This method allows you to install the configuration manager clients manually. The installation can be initiated by copying the CCMSetup. This program and its supporting files can be found in the Client folder of the System Center 2. Configuration Manager installation folder on the site server and on management points in your site. Group Policy based Installation – As the name says you can install the Configuration Manager client using group policy. When you assign the Configuration Manager client to computers by using Group Policy, the client installs when the computer first starts. When you publish the System Center 2. R2 Configuration Manager client to users by using Group Policy, the client displays in the Control Panel Add or Remove Programs for the computer for the user to install. Using Logon Scripts – Configuration Manager 2. R2 supports logon scripts to install the System Center 2. R2 Configuration Manager client software. You can use the program file CCMSetup. Using Computer Imaging – You can preinstall the Configuration Manager 2. R2 client software on a master image computer that will be used to build computers in your enterprise. When computers are imaged from this master image, they will contain the Configuration Manager 2. R2 client and must complete site assignment when installation is complete. Upgrade Installation – This method uses your existing software distribution infrastructure to upgrade the client. Upgrade installation requires prior discovery and site assignmentof the system. The above methods are some of the ways where the SCCM admin can use for Configuration Manager 2. R2 Client Installation. In this post we will install the Configuration Manager 2. R2 Client by enabling the automatic sitewide client push installation method. For Client push installation you can check this post. From the Configuration Manager Console Click Administration, Under Site Configuration, Click Sites, at the top ribbon under Client Installation Settings, click Client Push Installation. In the General tab check the box for Enable Automatic site wide client push installation. Under System types select Servers and Workstations. If you want to install the client agent on domain controllers choose the option “Always Install configuration Manager Client on Domain Controllers“, with this the client agents will be installed on all the newly discovered Domain controllers. If you want to have an option of pushing the client agent to domain controllers during client installation wizard then choose the option “Never Install Configuration Manager Client on Domain Controller unless specified in Client Push Installation Wizard”. Click on Apply. Select the Accounts tab, the account that you will add here must have local administrator rights on every computer on which you want to install the client. I will choose “PRAJWAL\sccmadmin” as the user account for deploying client agent on systems. Once you have added the account, Click Apply and OK to close the properties page. After few minutes we see that ccmsetup. The below screenshot is from one of the machine named WIN7. PRAJWAL. LOCAL. Similar screenshot from one of the machine named WIN8. PRAJWAL. LOCAL. Before the client agent is installed, the files required for installation is first copied to the system under the path \windows\ccmsetup. After few minutes we see that the configuration manager 2. R2 client has been installed on 2 machines (WIN7 and WIN8) and the Client Activity status is Active. Installing the Configuration Manager Client through Client Push Wizard. In the above example we enabled automatic sitewide client push installation and the client were installed on few systems. While configuring client push installation we had specified not to install the configuration manager clients on domain controllers automatically when discovered, however the client could be installed through client push installation. In this example we will install the configuration manager client to one machine Named AD (Domain controller). From the Configuration Console, Click Assets and Compliance, Under Devices Select All Systems. Right Click on the system where the client has to be pushed. Click Install Client. Click Next. Specify Client Push Options – Since we are installed the client on the system which is a domain controller, check the box for Allow the client software to be installed on domain controllers. Also check Install the client software from a specified site and click Next. Click Close. If we take a look at ccm. SCCM server, we see the complete process right from how the request is sent to server and how the client is installed.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
August 2017
Categories |